Indoor construction should pay attention to points

In general, the following points should be noted in the renovation project:

First, the home improvement should pay attention to the floor of the building not all paving marble. Marble is dozens of times heavier than floor tiles and wooden floors. If the floor is entirely covered with marble, the floor may become overwhelmed. Especially in the second floor or above, the weight of the ground decoration materials must not exceed 40 kg/m2 because of the house decoration not identified by the housing safety appraisal station.

Second, to carry out room decoration, do not arbitrarily wear holes in the load-bearing wall, dismantle the walls connecting the balconies and doors and windows, and expand the size of the original doors or windows or build windows and doors. This practice will cause partial cracks in the building and severely affect the earthquake resistance, thus shortening Building life.

Third, the decoration of balconies and bathrooms should try to use a small amount of decoration materials, because the over-loading of balconies will overturn.

Fourth, toilet water is a key link in the decoration. The general practice is, before decorating the toilet room, first stop the floor drain, put more than 5 cm of water, conduct the watering test, if it leaks, you must redo the waterproof; if you do not leak, you should also carefully lay the ground in the construction , Do not damage the waterproof layer and arbitrarily change the water and heating system.

Fifth, in the decoration of the house in order to pursue luxury, in the four walls covered with plates, ceilings inlaid with two or three-dimensional suspended ceiling, this kind of decoration practices are not desirable. Because the four walls are covered with plates, occupying a larger space will reduce the area of ​​the entire space, the cost is also high, and it is not conducive to fire prevention. A low ceiling will create a sense of depression in the entire room.

6. Use copper wire when selecting wires and avoid using aluminum wires. Due to the poor electrical conductivity of the aluminum wire, the wire is prone to heat, the connector is loose, and even a fire is caused during use. In addition, during construction, attention should also be paid to the fact that it is not possible to dig trench-embedded wires directly on the wall, and regular bushings should be used to prevent leakage and fire.

7. During the construction, attention should be paid to avoiding holes, holes, hanging ceilings, and installing art lighting fixtures in the concrete circular hole plate.

8. Interior decoration shall ensure the safety requirements for gas pipelines and equipment. Do not arbitrarily change or dismantle the pipeline so as not to affect the normal operation of the system. In addition, it should be noted that the net distance between the electrical pipeline and equipment and the gas pipeline shall not be less than 10cm, and the net distance between the electric wire and the gas pipeline shall not be less than 3cm.

9. Don't put the gas stove on the wooden cabinet in the kitchen decoration, and you can't wrap the gas valve in the wooden cabinet. Once the ground cabinet is on fire, the gas master valve will be difficult to close in the fire, and the consequences will be disastrous.

10. Do not damage the original wire or plumbing pipes when drilling holes. When the electrical conduit is laid, it is necessary to thread the conduit. Do not bury the wire directly on the ground or in the wall. This is not only unsafe, but it cannot be repaired once it is damaged. After the plumbing pipe is applied, the plumbing pipe must be pressure tested. After the pipe is qualified, the next process is performed to prevent the pipe from leaking and causing damage.

Twelve, kitchens and toilets need to do waterproof parts, must be done after the completion of water-blocking water test, after qualifying posted.

Thirteen, wire connectors must be tinned, the joints of the kitchen and bathroom are recommended to do waterproof treatment, joints can be used high-pressure self-adhesive tape and black tape for dressing.

14. Lamps with a weight of more than 3 kg must be fixed on bolts or embedded hooks. Use of wood wedges is prohibited. Fixtures with a height of less than 2.4 meters must be protected and grounded. The toilet must be waterproof.

Fifteen, circuit construction must be standardized, for example, the diameter of 16mm line tube to wear up to three lines; strong and weak wires to more than 50cm, to avoid signal interference; concealed line tube to be fixed firmly, otherwise the wall is easy to crack.

Entrance decoration children's room decoration marble window decoration space house floor tile marble floor tile floor cabinet kitchen cabinet door bathroom door bathroom ceiling material bathroom door size bathroom size bathroom ceiling bathroom waterproof bathroom leak

Biodegradable Straw (PLA)