Neutral and acid salt spray box difference

Core Tip: The salt spray box is one of the most common products in the ring test industry. People who have been in contact with the ring test industry know the salt spray box. Recently, the demand for acid salt spray boxes on the market is increasing. Big (also known as CASS salt spray box), all know that this is a Japanese standard.

So what are the differences between neutral and acidic salt spray boxes?

First, the temperature in the test method is different:

Brine test: a. Laboratory: 35 ° C ± 1 ° C, b. Saturated air tank: 47 ° C ± 1 ° C

Corrosion test: a. Laboratory: 50 ° C ± 1 ° C, b. Saturated air barrel: 63 ° C ± 1 ° C

Secondly: the finished material is different: the former full-box material can be as long as the traditional PVC reinforced hard plastic plate, and the latter requires an upgraded version of the PP plate material. Because PP boards are more resistant to high temperatures and strong acids than PVC sheets.

Furthermore: the test methods are different:

Neutral salt spray box according to GB/T2423.17-2008, GB/T2423.18-2000 "Basic procedures for electrical and electronic products test Ka", salt spray test methods and GB/T10125-1997, GB/T10587-2006, GB10593. 2-1990, GB/T1765-1979, GB/T1771-2007, GB/T12967.3-2008, GB/T5170.8-2008 and other national standard customization, acid salt spray box in addition to the test methods specified in the national standard, also need Expand IEC, MIL, DIN, ASTM, IS, CNS and other standard settings.

Global hardware network

Concerned about surprises

Label: the difference between neutral and acid salt spray box

Previous: The role of illuminance meter in daily life Next: Tips for identifying the quality of alcohol-based oil

OLED Chemicals

Oled Chemistry,Cas 4431-83-8,99% Bis 2-Methoxyethoxy Methane,4431-83-8 99%

HENAN BON INDUSTRIAL(CHEMICAL) CO.,LTD , https://www.bonchemical.com